General Image Stitching MPR IQQA



e-PACS 2000 DS, an integrated platform for medical image diagnosis, pertains to a degree of standardization of clinical application modularizations to allow for combinations and large variety of compatible units. It enhances the flexibility for professionals to deal with various clinical images and predigests healthcare workflow, owning to its specific optimization capability and wide medical standards compatibility.

Inherent with a PPACS (Personal PACS Server) module, e-PACS 2000 DS possesses the most state-of-the-art performance respecting to image retrieving, communication, archiving as well as optimization. It can be used as a solo post-process workstation parallel with an imaging modality or to establish a clinical cooperation network combining with RIS/HIS, imaging modalities and storage medium. Its intuitive Graphic User Interface and Window based operation system make it easy and fast to use.

Flexibility:
Adaptive UI resolution to support various monitor

 - 5M, 3M, 2M etc.
 - Landscape and portrait display.
  Allow for combinations and large
  variety of configurable modules
 - Stitching
 - MPR
 - SymphonyTM
 - IQQA
 - Reporting
 - Tele-radiology

Compatible with DICOM 3.0,
 1. DICOM Storage SCU, DICOM Storage SCP
 2. DICOM Storage Commitment SCU, Storage Commitment SCP
 3. DICOM Query/Retrieve SCU, Query/Retrieve SCP
 4. DICOM Verification Service SCU/SCP
 5. DICOM Media Service, FSR/FSC
 6. DICOM Print SCU

This module can seamlessly stitch a set of overlapping DR or DF images for the same patient to build a panoramic image. The overlapping images must be taken at the same time with the patient keeping still.

Key Features
 - The number of overlapping images can be two or more. The height
  of each image's overlapping region should be more than one sixth
  of theimage's height.
 - The order of these input images is adjusted automatically to
  guarantee the anatomy structures represented by them are in the
  rightorder.
 - For two adjacent images, the search of their corresponding region
  is carried out automatically, this could override manually.
 - For overlapping areas in adjacent images, image intensities are
  blended to create a seamless boundary between the images.
 - The panoramic image is rendered an optimized displaying curve by
  default. This curve can be adjusted manually.
 - The registration can also be done by manually translating the
  images.

Professional tools
 - Spine evaluation: measurement of Scoliosis angles, Kyphosis
  angles, Spinal misalignment;
 - Leg overview: measurement of differences in bone length,
  measurement of femur neck angles, leg axis angles etc.






Scoliosis evaluation

Femur evaluation

Based on the transverse series, coronal series, Sagittal series, to reconstruct slices in any direction as parallel slices or radial slices.




To reconstruct a parallel series:
  Slice number and inter-gap is free to define
To reconstruct a parallel series:
  Slice number and inter-gap is free to define

IQQA adopts independent innovative technique which is protected by patent, including advanced artificial intelligence, computer vision, pattern recognition and information combine, etc. combining the knowledge and experience of world-famous radiologists and clinicians. Taking the convenience and practice needs of hospital and doctors into account, this system provides intelligent real-time interaction and fully automatic compatible focus diagnosis, thus improve the confidence, precision, coherence and diagnosis efficiency of radiology doctors.

As a new generation of medical computer-aided diagnostic product, it has passed FDA qualification by USA and SFDA qualification by China, it can sale in Europe, America and China.

The system help the doctors display, identify, analyze and summarize the lung nodules in the X-ray digital chest image.

Case 1: computer automatically point out nodules shadow between right upper lung and rib.(10mm) Case 2: computer automatically point out two nodules —— left upper lung and right lower lung
IQQA-chest is a trademark used and registered by EDDA.
(http://www.edda-tech.com)

  Any further inquires please contact:ecom_info @ e-comtech.com
Copyright (C) 2007, E-COM Technology CO.,LTD. 粤ICP备05099618号
All rights reserved.